Related Experiment Video
Updated: Aug 29, 2026

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
Published on: January 10, 2025
Comparability across infrared spectroscopy techniques and substrates for bioanalytical applications
Shuxia Guo1,2, Supatcharee Cael2, Samir F El-Mashtoly1,2
1Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI) Helmholtzweg 4 07743 Jena Germany shuxia.guo@leibniz-ipht.de.
Abstract:
The development of quantum cascade lasers (QCLs) brought new possibilities in infrared (IR) spectroscopy for bioanalytical applications, offering highly enhanced resolution, sensitivity, speed, and multi-modal capability. This has been supported by QCL-based IR techniques, including the laser direct infrared (LDIR) and optical photothermal IR (O-PTIR) methods. Despite their vast strengths, the comparability of these IR techniques with the established Fourier transform infrared (FTIR) spectroscopy technique remains an open question. In this study, we systematically evaluate and compare O-PTIR, LDIR, and FTIR spectroscopy using six representative biologically relevant samples (ATP, brain lipid extract, cholesterol, glycogen, lysozyme, and urea) and three commonly used substrates (CaF2, silicon, and MirrIR). The measurements were generally performed in the single-point mode, with brain lipid and urea measured additionally in the mapping mode to investigate the influence of sample heterogeneity. On this basis, we examined three sources of variability in this study: sample heterogeneity, IR technique, and substrate. The variability was characterized from the perspective of the band intensities, band positions, band widths, and spectral similarities based on the Pearson's correlation coefficient. Overall, the measurements demonstrate clear differences across both techniques and substrates. The LDIR measurements are largely different from FTIR and O-PTIR measurements, while CaF2 exhibited better stability than MirrIR (Kevley) and silicon. More importantly, we found that the substrate plays a role in band positions, while the variability across IR techniques does not show clear patterns. With this study, we expect to draw attention to the unavoidable spectral variability in IR measurements across both IR techniques and substrates. This should be carefully considered, especially in multi-center studies.
More Related Videos
08:51Atomic Force Microscopy Combined with Infrared Spectroscopy as a Tool to Probe Single Bacterium Chemistry
Published on: September 15, 2020
11:05High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Applications of IR Spectroscopy: Overview
IR Frequency Region: Fingerprint Region
The...
IR Spectrometers
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...