Minimizing Risk of Load Redistribution Attacks on Electric Grids in the Presence of Insider Threats
Lujia Zhan1, Saharnaz Mehrani2, Chengzhi Xie1
1Department of Electrical and Computer Engineering, School of Engineering and Applied Science, The George Washington University, Washington, District of Columbia, USA.
Abstract:
Malicious and negligent insiders pose significant security risks to mission-critical systems like electric power grids due to their high privileges in increasingly digitized infrastructures. This paper investigates the vulnerability of smart power grids to load redistribution (LR) attacks in the presence of insider threats. We introduce a stochastic optimization model to minimize the expected risk of high operation costs due to LR attacks by protecting critical grid components and deploying detection technologies, such as honeypots, to detect insider threats and prevent information leakage. Our model accounts for uncertainties in insider presence, honeypot effectiveness, and attack targets, and uses the conditional value-at-risk (CVaR) measure, which can be adjusted based on the decision-maker's conservatism. In addition, it accounts for real-time power demand variations and dynamic false-data injection by attackers. To enhance tractability, we transform our model, originally formulated as a trilevel mixed-integer nonlinear programming (Tri-MINLP) problem, into an approximate single-level mixed-integer linear programming (MILP) formulation. We apply our proposed model to the IEEE 14-bus test system, and our results highlight the effectiveness of our approach in lowering the risk of high operation costs due to LR attacks. In addition, we present several insights by assessing the impact of key factors on the expected financial risk of attacks, including the protection budget, insider-threat likelihood, honeypot-detection effectiveness, and the defender's decision-making conservatism.
Related Concept Videos
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...