Related Experiment Video
Updated: Aug 31, 2026

Lab-Scale Model to Evaluate Odor and Gas Concentrations Emitted by Deep Bedded Pack Manure
Published on: July 19, 2018
Influence of measurement method, measurement height, and sampling location on carbon dioxide and ammonia
Thies J Nicolaisen1, Nina Volkmann1,2, Lena Brügge1,3
1Institute for Animal Hygiene, Animal Welfare and Farm Animal Behaviour, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
Abstract:
Low air quality and the presence of harmful gases such as ammonia can have detrimental effects on the health and welfare of pigs. Excessive concentrations of these gases are particularly common in negative pressure ventilated barns found in conventional husbandry systems. There are various devices and guidelines available for measuring harmful gases in such environments. In this study, ammonia and carbon dioxide were measured using three different devices. Measurements were taken across four production cycles in six pens at two different heights (0.6 m, within test pens; 1.5 m, representing human working height). The measurement results for ammonia and carbon dioxide obtained with the three different methods differed significantly from one another. Comparison of the two measurement heights revealed no significant difference for ammonia. However, measurement height had a significant effect on carbon dioxide concentrations. Furthermore, the location of the sampling points (test pens) within the compartment significantly influenced the measured concentrations of both ammonia and carbon dioxide, indicating spatial variability. When assessing air quality in a barn, it is advisable to use two different measurement systems for ammonia and carbon dioxide to ensure reliable results. Measuring ammonia does not necessarily have to be performed at animal height, as its vertical distribution was found to be uniform within the compartment. However, the location of the sampling points significantly influenced both ammonia and carbon dioxide concentrations. Therefore, measurements should be conducted at multiple locations within a compartment to capture spatial variability and to determine the most appropriate position for stationary sensors.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020