Innovative Strategies for Organ Preservation in Heart Transplantation: Uniform Cooling Preservation and Ex-situ Normothermic Perfusion
Published on: November 28, 2025
The Cold Truth: Myocardial Temperatures and Graft Function Achieved With Cold Static Storage
Nina Uzoigwe1, Caroline A Magro1, Katherine G Phillips1
1Department of Cardiothoracic Surgery, NYU Langone Health, New York, NY, USA.
Abstract:
We aimed to investigate myocardial temperatures of allografts after removal from cold static storage (CSS) and the relationship between temperature and early outcomes of heart transplantation (HT). Between January and September 2024, 22 allografts preserved with CSS underwent prospective temperature measurements at the left ventricular free wall (LVFW) and interventricular septum; preservation solution temperatures were also measured. Median LVFW temperature was 4.0°C, septal temperature was 3.9°C, and solution temperature was 3.7°C. LVFW and septal temperatures were significantly correlated (p < 0.001), as were septal and solution temperatures (p = 0.03). Ischemic time inversely correlated with solution temperature (p = 0.021), and septal thickness correlated with septal temperature (p = 0.04). One patient developed severe primary graft dysfunction, and 30-day recipient and graft survival were 100% (22/22). We conclude that CSS maintains myocardial temperatures near 4°C, and it can achieve excellent post-HT outcomes with a low incidence of PGD.
More Related Videos
09:29Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
Published on: August 13, 2014
08:22In vitro Assessment of Myocardial Protection following Hypothermia-Preconditioning in a Human Cardiac Myocytes Model
Published on: October 27, 2020