Related Experiment Video
Updated: Sep 4, 2026

Large Volume Blood Collection from Swine for In Vitro Applications: Use of Intracardiac Cannulation and a Vacuum Pump as a Terminal Procedure
Published on: July 25, 2025
Development and field validation of a large-volume bag-based whole-blood collection method in donor dairy cows
Filippo Rigo1, Luca Panozzo1, Giacomo Catarin1
1Department of Animal Medicine, Production and Health, University of Padua, Padua, Italy.
Abstract:
Obtaining sterile anticoagulated whole-blood units is a key prerequisite for downstream laboratory and clinical applications involving blood-derived products. In bovine medicine, however, published information on blood collection into bags is mainly embedded in transfusion-oriented references or broader downstream studies, while formal validation of donor-oriented collection methods remains limited. The aim of this study was to develop and field-validate a large-volume bag-based method for whole-blood collection in donor dairy cows under commercial farm conditions. Whole-blood collections were performed in clinically healthy donor dairy cows using a jugular venipuncture protocol that was progressively refined during field validation. A true sequential multi-bag setup, enabled by extension tubing and a perforable connection device, was introduced on 24 October 2022. Protocol validation was based primarily on procedural success, defined as a bacteriologically negative blood unit with a collected volume of at least 400 mL per bag. A total of 294 procedures were included. Overall, 228/294 procedures (77.6%) were classified as successful, 48/294 (16.3%) as suboptimal, and 18/294 (6.1%) as failed. The median collected volume per procedure was 410 mL (IQR 400-430; range 124.5-1,280 mL). Overall, 276/294 collections (93.9%) were bacteriologically negative. Within the single-bag phase, later collection dates were associated with a lower probability of bacteriological positivity, supporting a learning-curve effect on microbiological reliability. Later implementation of the sequential multi-bag setup was associated with a higher total volume per procedure, without an apparent loss of microbiological safety. In conclusion, this large-volume bag-based protocol proved feasible for whole-blood collection in donor dairy cows under field conditions and may provide a practical upstream basis for subsequent laboratory applications and downstream processing workflows.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
12:54Determination of Vaccine Immunogenicity Using Bovine Monocyte-Derived Dendritic Cells
Published on: May 19, 2023