Autoerotic death caused by neck compression using a sphygmomanometer cuff: a case report with integrated forensic
Sari Matsumoto1, Shojiro Takasu1
1Department of Forensic Medicine, Jikei University School of Medicine, Nishishinbashi 3-25-8, Minato-ku, Tokyo 105-8461, Japan.
Abstract:
Autoerotic death, an accidental fatality that occurs during self-stimulatory behavior intended to enhance sexual arousal, poses a diagnostic challenge in distinguishing it from suicide and homicide. Most cases involve neck compression or asphyxial mechanisms, typically through the use of ligatures or suffocation devices. However, reports describing the use of medical devices in an autoerotic context remain limited. We report the case of a man in his 30s who died in his residence after a sphygmomanometer cuff was applied around his neck. He was partially unclothed, and no signs of struggle or third-party involvement were identified. Multiple video recordings stored on a tablet documented repetitive behavior in which the cuff was inflated around the neck during genital stimulation. Autopsy revealed congestion of the head and face, conjunctival and mucosal petechiae, and scattered intramuscular hemorrhagic foci in the tongue, without fractures of the hyoid bone or thyroid cartilage. These findings were compatible with compression produced by an inflatable cuff. Toxicological analyses did not reveal any lethal substances. The cause of death was determined to be asphyxia resulting from neck compression. Although no recording of the fatal event was available, the combined scene findings, digital evidence, and autopsy results supported the conclusion of an accidental autoerotic death. This case highlights the value of integrating scene investigation, digital evidence, and autopsy findings when determining the manner of death in suspected autoerotic fatalities.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.