Related Experiment Video
Updated: Sep 6, 2026

Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Fully coupled patient-specific fluid-structure interaction modeling of post-TAVI hemodynamics compared with
Chiara Catalano1, Deniz Ozturk2, Maria Bastron2
1Department of Research, IRCCS ISMETT, Via Tricomi, 5, Palermo, Italy.
Abstract:
To develop a fully coupled, patient-specific fluid-structure interaction (FSI) framework for quantitative assessment of post-transcatheter aortic valve implantation (TAVI) hemodynamics and valve biomechanics, and to compare selected simulation-derived hemodynamic indices with post-procedural echocardiographic measurements. Patient-specific geometries were reconstructed from pre-operative computed tomography angiography in five subjects treated with SAPIEN 3 Ultra (S3) devices. Structural TAVI deployment was simulated using Abaqus/Explicit and subsequently coupled with FlowVision for performing a two-way post-TAVI FSI analysis. Personalized boundary conditions were derived from clinical measurements, including heart rate, blood pressure, and echocardiographic flow data. Predicted peak velocity, effective orifice area (EOA), and transvalvular pressure gradients (TPG) were quantitatively compared with post-procedural echocardiography using empirical cumulative distribution functions and area-based error metrics. The FSI framework reproduced realistic leaflet kinematics and patient-specific flow patterns, highlighting marked inter-patient variability despite identical device types. Average of predicted peak systolic velocity (2.66 ± 0.59 m/s) and TPG (22 ± 10.7 mmHg) showed good agreement with echocardiographic measurements as the area metric was below 10% for both peak TPG and velocity. Larger discrepancies were observed for EOA due to patient variability and reliability of echocardiographic measurements. The model additionally quantified biomechanical and hemodynamic parameters, including leaflet stress, time-averaged wall shear stress (TAWSS), and blood residence time (BRT). The proposed fully coupled FSI framework enables patient-specific analysis of post-TAVI hemodynamics and valve mechanics for S3 balloon-expandable intra-annular system. The preliminary comparison with echocardiographic measurements showed good agreement for peak velocity and peak TPG, while larger EOA discrepancies highlight the need for further clinical benchmarking using larger cohorts and more direct measurement modalities.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Typical Model Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...