Discrepancy in applied tidal volumes between t-piece and lung level during delivery room stabilization - a case
Alexia Zanghi1, Maria Wall1, David G Tingay2,3
1Division Neonatology Department of Pediatrics, Dr. von Hauner Children's Hospital, LMU Medizin, LMU University Hospital, Ludwig-Maximilians-Universität München, Munich, Germany.
Abstract:
We present data of a preterm infant at 28 4/7 weeks gestation with inadequate response to non-invasive ventilation after birth who was intubated five minutes after delivery. During non-invasive stabilization, we noted a discrepancy between the displayed tidal volumes on the respiratory function monitor (RFM) and the real-time electrical impedance tomography (EIT) measurements. While expiratory tidal volumes on the RFM were in the recommended target of 4-6 mL/kg, EIT showed only minimal tidal volumes (corresponding to approximately 1-3 mL/kg), which was more consistent with the clinical impression of the neonate. After intubation, tidal volumes shown on RFM and EIT were similar, suggesting that RFM may be unreliable during non-invasive ventilation, possibly due to the large compliance of the nasopharyngeal space. EIT may be a helpful additional clinical tool in selective cases in the delivery room.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Atelectasis II: Pathophysiology
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...