Portal Vein Doppler Parameters as Indicators of Volume Status in Hemodialysis Patients Using Wireless Ultrasound
Shaymaa E Mohammed1, Motaz Fathy1, Alaa Abd El-Hamid1
1Department of Internal Medicine, Faculty of Medicine, Kasr Al-Ainy Hospital, Cairo University, Cairo, EGY.
Background:
Accurately assessing fluid status is a critical yet challenging clinical skill. While hypovolemia marked by low blood pressure and poor tissue perfusion is a major concern, hypervolemia can also cause harmful complications. Because there is no single gold standard test, clinicians must master various non-invasive bedside tools to achieve proper fluid balance.
Objective:
The objective of this study is to investigate the potential clinical value of portal vein (PV) Doppler parameters in assessing volume status and to evaluate the utility of PV Doppler parameters for assessing volume status. Methods: A cross-sectional study was conducted on 100 Egyptian patients from a dialysis unit. All participants underwent a medical history review, clinical examination, and laboratory tests including complete blood count, liver function tests, kidney function tests, and assessment of Doppler parameters of the PV pre-dialysis and post-dialysis.
Results:
The mean age of cases was 42.70 (± 12.25), while the mean age of control subjects was 45.57 (± 10.32), with no statistically significant difference in age between cases and control subjects (p-value 0.24). Female patients represented 48% and male patients 52% in cases, while in control, female subjects accounted for 46.7% and male subjects 53.3%, with no statistically significant difference between cases and control (p-value 0.898). A significant improvement was observed in the PV diameter post-dialysis (p-value 0.004) and pulsatility index (p-value < 0.001). Additionally, there was a significant improvement in the PV waveform (p-value < 0.001).
Conclusion:
PV Doppler parameters reflect systemic venous congestion and changes in volume status in hemodialysis patients. Therefore, they can be used to assess pulmonary congestion in this patient population.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Hemodialysis I: Introduction
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...