Related Experiment Video
Updated: Sep 10, 2026

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Ce3+-Mediated Self-Calibrating NIR-II Nanothermometer Enables Reliable Real-Time In Vivo Temperature Monitoring
Mingzhu Yang1, Zi-Han Chen1, Hongyue Liu1
1Laboratory of Advanced Materials, College of Smart Materials and Future Energy, Department of Chemistry, New Cornerstone Science Laboratory, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Shanghai Wusong Laboratory of Materials Science, Fudan University, Shanghai, P. R. China.
Abstract:
Precise temperature monitoring in living systems provides valuable insights into physiological processes, thereby motivating the development of luminescent nanothermometers for noninvasive thermometry. However, wavelength-dependent tissue absorption and scattering inevitably distort luminescence signals, resulting in inaccurate temperature measurements. Here, we report a self-calibrating luminescent nanothermometer (NaYF4: Tm@NaYF4: Er@NaYF4@NaYbF4: Er/Tm/Ce@NaYF4) that utilizes the Er3+ and Tm3+ emissions at 1532 and 1626 nm in the low-scattering long-wavelength near-infrared region (NIR-II-L, 1500-1900 nm) to achieve reliable in vivo thermometry. By identifying Ce3+ as a critical mediator that suppresses temperature-sensitive phonon-assisted energy transfer (PAT) between Tm3+ and Er3+, we inversely engineered the Ce3+-doped Tm3+/Er3+ outer module to generate a thermally inert reference ratio for calibrating the PAT-enhanced thermometric ratio of the inner Tm3+/Er3+ module. The resulting self-calibrating signal minimized depth-induced distortion with only 2.9% fluctuation through 10 mm of tissue, enabling reliable dynamic thermometry at a high temporal resolution of 20 fps. In vivo studies further demonstrated that the nanothermometer enabled accurate intestinal thermometry and intratumoral temperature monitoring during photothermal therapy. This work provides new insights into self-calibrating luminescent nanoprobes for accurate real-time sensing in living systems.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...

