Related Experiment Video
Updated: Sep 10, 2026

Detection and Removal of Nuclease Contamination During Purification of Recombinant Prototype Foamy Virus Integrase
Published on: December 8, 2017
Efficient filtration of fibrinogen solution by a virus removal filter
Tomona Harada1, Kumiko Michikawa1, Mana Konno2
1Technology Development Department, R&D and Business Development, Asahi Kasei Life Science Corporation, Miyazaki, Japan.
Abstract:
Historically, achieving efficient filtration of fibrinogen solutions using virus removal filters has been challenging due to the fibrinogen's tendency to aggregate and its molecular size and structure. In this study, the feasibility of fibrinogen using the filtration the Planova™ 20 N filter and its virus removal efficacy under optimized filtration conditions were investigated. Optimization of arginine (400 mM) and fibrinogen (2 mg/mL) concentration in the solution, along with pre-filtration to remove the aggregates, was essential for achieving efficient filtration. Notably, Planova 20 N filter exhibited robust virus removal performance and the biological activity of fibrinogen including its clotting function was preserved, indicating that protein integrity was maintained throughout the process.