Related Experiment Video
Updated: Sep 10, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Effects of spiral deflation and warming on cuff diameter, insertion force, extubation, and sealing performance in
Hiroki Yonezawa1, Michiko Kinoshita2, Chiaki Murakami2
1Department of Anesthesiology, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima-shi, Tokushima, Japan.
Abstract:
Cuffed tracheal tubes are widely used in paediatric airway management, but passage through the relatively narrow subglottic airway may increase insertion resistance and risk mucosal trauma. This study evaluated whether spiral deflation (i.e. folding the cuff inward like an umbrella) and warming the tube could reduce cuff diameter and insertion force in a simulated trachea. Four commercially available polyvinyl chloride-cuffed tubes with an internal diameter of 5.0 mm (PORTEX® (Smiths Medical International Ltd, Ashford, UK), Sheridan® (Teleflex Inc., Morrisville, NC, USA), Shiley™ (Medtronic, Minneapolis, MN, USA), and VentiSeal™ (Flexicare Medical Ltd, Mountain Ash, UK)) were examined. Spiral deflation significantly reduced cuff diameter, with reductions of (mean difference, MD) -3.6 mm (95% confidence intervals, CI -4.5 to -2.7, P <0.001), -2.8 mm (-4.0 to -1.6, P <0.001), -3.5 mm (-5.0 to -2.1, P=0.001), and -4.9 mm (-6.0 to -3.9, P <0.001), respectively. Spiral deflation also decreased insertion force, with reductions of (MD (CI)) -1.01 N (-1.52 to -0.50, P=0.008), -0.34 N (-0.63 to -0.05, P=0.115), -0.49 N (-0.61 to -0.37, P <0.001), and -2.33 N (-3.83 to -0.84, P=0.028), respectively. Additional warming at 40°C further lowered insertion force, with reductions of (MD (CI)) -0.12 N (-0.19 to -0.05, P=0.020), -0.06 N (-0.08 to -0.03, P=0.002), -0.07 N (-0.11 to -0.03, P=0.010), and -0.48 N (-0.86 to -0.11, P=0.068), respectively. Spiral deflation with warming did not affect extubation force or sealing performance. Overall, spiral deflation effectively reduced cuff diameter by approximately 25% and lowered insertion force, while warming further enhanced ease of insertion. These approaches did not compromise sealing or extubation performance.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...

