Related Experiment Video
Updated: Sep 10, 2026

Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
Published on: July 11, 2025
A Quality Assessment Rubric for Artificial Intelligence-Generated Patient-Friendly Radiology Reports
Bonnie A Armstrong1, Arogya Koirala1, Hye Sun Na1
1Department of Radiology, Stanford University, Palo Alto, California 94305, United States.
Abstract:
Background: Artificial intelligence (AI) tools are being used to translate radiology reports into plain language, but translation errors may compromise comprehension and safety. Objective: To develop and evaluate a rubric for assessing the quality and safety of AI-generated patient-friendly radiology reports. Methods: In this prospective study (conducted from February 2025 to December 2025), survey-workshop cycles, involving lay participants and a multidisciplinary panel, were used to develop a rubric for grading AI-generated patient-friendly report quality across core attributes and determining whether such reports are safe for patient distribution. ChatGPT-4.1 and Claude-4.0 were used to generate patient-friendly reports of varying quality based on radiology report impressions from a public dataset and prespecified quality targets across attributes. Research-team members, additional lay participants and radiologists, and ChatGPT-5 evaluated these patient-friendly reports using the rubric. Results: Development included 19 participants (39±7 years; 11 women, 8 men); evaluation included six research-team members and 111 additional participants (47±18 years; 43 women, 68 men). The final rubric included five core attributes-clarity, content, certainty, tone, verbosity-each graded on a 3-point scale; by the rubric's decision rule, patient-friendly reports assessed as grade 1 (unsafe or unacceptable) in any attribute other than verbosity are unsafe for distribution and warrant withholding. Lay and radiologist research-team members (n=3 participants each; 60 reports) had almost-perfect intergroup agreement (α=0.87) for overall grade assignments. Additional lay (n=19) and radiologist (n=12) participants, each evaluating six reports, had moderate (α=0.51) and substantial (α=0.65) interreader agreement, respectively, for overall grade assignments and 91.2% and 95.8% agreement, respectively, between subjective and rubric rule-based distribution decisions. In wider field testing, 80 lay participants (480 reports) had moderate agreement (κ=0.43) with prespecified reference-standard grades; subjective distribution decisions had 73.5% agreement with rule-based distribution decisions. Across 480 reports, AI had moderate agreement (κ=0.44) with prespecified reference-standard grades; rule-based distribution decisions using AI-assigned grades had 88.1% agreement with rule-based distribution decisions using reference-standard grades. Conclusions: The rubric may provide a standardized safeguard before release of AI-generated patient-friendly reports. Clinical Impact: Although requiring further training and validation, AI rubric application could enable scalable quality assurance and safer clinical integration of AI-generated communications.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...