Optimising nonlinear calibration of glass pH electrodes over the pH range -4.5 to 15.5 using improved statistical

Sarawud Saleesongsom1, Yves Plancherel1, Dominik Weiss1

  • 1Department of Earth Science and Engineering, Imperial College London, South Kensington, London, SW7 2AZ, United Kingdom.

Talanta
|September 9, 2026
PubMed

Related Concept Videos

Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calculating pH Changes in a Buffer Solution02:45

Calculating pH Changes in a Buffer Solution

A buffer can prevent a sudden drop or increase in the pH of a solution after the addition of a strong acid or base up to its buffering capacity; however, such addition of a strong acid or base does result in the slight pH change of the solution. The small pH change can be calculated by determining the resulting change in the concentration of buffer components, i.e., a weak acid and its conjugate base or vice versa. The concentrations obtained using these stoichiometric calculations can be used...
Titration of a Weak Acid with a Strong Base01:30

Titration of a Weak Acid with a Strong Base

In titrating a weak acid with a strong base, different calculation methods are applied at various stages. Initially, the pH of a weak acid like acetic acid is calculated using its dissociation constant (Ka) and an ICE table. Upon addition of a strong base such as sodium hydroxide, a buffer forms, and its pH is determined using the Henderson-Hasselbalch equation. As more base is added and the titration reaches the halfway point, the pH becomes equal to the pKa of the acid, indicating equal...
Buffer Effectiveness02:19

Buffer Effectiveness

Buffer solutions do not have an unlimited capacity to keep the pH relatively constant . Instead, the ability of a buffer solution to resist changes in pH relies on the presence of appreciable amounts of its conjugate weak acid-base pair. When enough strong acid or base is added to substantially lower the concentration of either member of the buffer pair, the buffering action within the solution is compromised.
The buffer capacity is the amount of acid or base that can be added to a given volume...
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as: