Related Experiment Video
Updated: Sep 11, 2026

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
MPISuperRes-PnP: a super-resolution zero-shot plug-and-play reconstruction algorithm for magnetic particle imaging
Vladyslav Gapyak1, Thomas März2, Andreas Weinmann3
1Institute for the Protection of Terrestrial Infrastructures, German Aerospace Center, Rathausallee 12, Sankt Augustin, NRW, 53757, Germany.
Objective:
Magnetic Particle Imaging (MPI) is a promising, emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and does not expose the specimen to ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution techniques are important. In this work, we propose an approach for super-resolution in MPI inspired by energy minimization. Approach. Different methods have been proposed for super-resolution in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate super-resolution into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser. Main results. We derive a super-resolution method for MPI based on a plug-and-play approach using a pre-trained denoiser in zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method on simulated data with realistic noise. Hyper-parameters are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We qualitatively show the applicability of our method on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). Significance. The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The super-resolution approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.
More Related Videos
09:55Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging: Tools for High-Quality Image Acquisition
Published on: January 5, 2024
07:12Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
Published on: January 6, 2026
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Super-resolution Fluorescence Microscopy