Related Experiment Video
Updated: Sep 11, 2026

Electrocardiogram Recordings in Anesthetized Mice using Lead II
Published on: June 20, 2020
Unexplained Syncope in Patients With Congenital Long QT Syndrome - Role of Implantable Loop Recorders in Diagnostic
Yuichiro Miyazaki1,2, Takeshi Aiba1, Koichi Kato3
1Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center.
Background:
Syncope is common in patients with congenital long QT syndrome (LQTS). However, not all episodes of syncope or loss of consciousness are caused by torsades de pointes (TdP); some are attributable to bradycardia or non-cardiac causes. This study investigated the clinical utility of implantable loop recorders (ILRs) in patients with LQTS presenting with unexplained syncope.
Methods And Results:
We retrospectively studied 18 patients with LQTS (7 with LQTS type (LQT) 1, 3 with LQT2, 1 with LQT3, and 7 genotype-negative LQTS) who underwent ILR implantation for recurrent syncope. Multiple causes of syncope were suspected in each patient; there were 14 cases of arrhythmia, 4 of epilepsy, 8 of neurally mediated syncope (NMS), and 9 of unknown cause. During a mean (±SD) follow-up of 37±22 months after ILR implantation, 8 (44%) patients experienced recurrent syncope. Four episodes were caused by TdP and the remaining 4 episodes were attributed to epilepsy or NMS (cardioinhibitory type). No significant difference was observed in baseline clinical characteristics between patients with and without TdP following ILR implantation, but female sex (P=0.051) and a higher Schwartz score (P=0.08) tended to be associated with TdP.
Conclusions:
Syncope in patients with LQTS is not always attributable to TdP, and non-arrhythmic causes should be considered. Although ILRs may aid in diagnostic evaluation, careful risk stratification remains essential in patients with suspected arrhythmic syncope.
More Related Videos
07:15Determining the Likelihood of Variant Pathogenicity Using Amino Acid-level Signal-to-Noise Analysis of Genetic Variation
Published on: January 16, 2019
09:20Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias I: Introduction
Dysrhythmias IV: Characteristics of Bradyarrhythmias