Related Experiment Video
Updated: Sep 12, 2026

Pipeline for Planning and Execution of Transcranial Ultrasound Neuromodulation Experiments in Humans
Published on: June 28, 2024
Evaluation-design effects and reference-CT-defined HU-class errors in brain MRI-to-CT synthesis on SynthRAD2023: a
Tatsuya Hayashi1, Shinya Kojima2, Norio Hayashi3
1School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan. hayashi.tatsuya@kitasato-u.ac.jp.
Abstract:
To quantify how evaluation design affects brain MRI-to-CT synthesis performance, we analyzed 180 MRI/CT pairs from three centers in the SynthRAD2023 Task 1 dataset. A lightweight 2D U-Net was trained with a common validation-based stopping rule under slice-random, patient-random, center-stratified size-matched patient-random, and three center-held-out designs. Comparisons were descriptive. The primary outcome was whole-mask mean absolute error (MAE), supplemented by MAE within reference-CT-defined Hounsfield unit (HU) classes. MAE (mean ± standard deviation) was 94.4 ± 3.0, 100.8 ± 1.3, and 105.2 ± 2.8 HU for the random designs and 187.4 ± 6.0, 160.6 ± 7.1, and 137.4 ± 5.1 HU for centers A, B, and C held out. Slice-random testing yielded lower MAE than patient-random testing. Center-held-out testing yielded higher MAE than the center-stratified comparator, although institutional and acquisition-domain effects could not be separated. Bone errors were high across designs; adipose-range and air errors were elevated in specific center-held-out tests.
More Related Videos
Related Concept Videos
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

