Related Experiment Video
Updated: Sep 12, 2026

Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for the Specific and Rapid Detection of Tilapia Lake Virus
Published on: May 18, 2020
Development of a rapid and visual ERA-LFD assay for sensitive detection of Ichthyophthirius multifiliis with
Xue-Mei Yuan1, Jing Chen2, Jing-Biao Jiao2
1College of Life Sciences, Xinjiang Normal University, Urumqi, China; Agriculture Ministry Key Laboratory of Healthy Freshwater Aquaculture, Key Laboratory of Fish Health and Nutrition of Zhejiang Province, Key Laboratory of Fishery Environment and Aquatic Product Quality and Safety of Huzhou City, Zhejiang Institute of Freshwater Fisheries, Huzhou, China.
Abstract:
Ichthyophthirius multifiliis is a highly pathogenic ciliate responsible for "white spot disease" in freshwater fish, causing significant economic losses to the global aquaculture industry. Early and accurate detection of this parasite is critical for disease control, however, current methods often require specialized equipment and trained personnel, limiting their applicability in resource-limited settings. In this study, a rapid, sensitive, and visual detection method for I. multifiliis was developed by combining enzymatic recombinase amplification (ERA) with lateral flow dipstick (LFD) technology. Specific primers and an internal probe targeting the mitochondrial cytochrome oxidase subunit I (COI) gene were designed. After optimizing the reaction conditions, the ERA-LFD assay achieved optimal performance at 43 ℃ for 18 min, with a detection limit of 100 copies/μL of recombinant plasmid DNA and the ability to detect as few as a single theront. The assay exhibited high specificity, showing no cross-reactivity with seven other common fish parasites (Argulus sp., Chilodonella uncinata, Cryptocaryon irritans, Trichodina sp., Gyrodactylus kobayashii, Trypanosoma sp., and Dactylogyrus sp.). Validation using experimentally infected goldfish (Carassius auratus) demonstrated 100% diagnostic concordance for both fish tissue and water samples. This ERA-LFD method combines isothermal amplification with visual readout, eliminating the need for thermal cyclers and specialized personnel. Its simplicity, speed, and high sensitivity make it a promising point-of-care testing (POCT) tool for early warning and surveillance of ichthyophthiriasis in aquaculture.
More Related Videos
05:23Use of Fluorescent Immuno-Chemistry for the detection of Edwardsiella ictaluri in channel catfish (I. punctatus) samples
Published on: May 10, 2011
06:57Loop-mediated Isothermal Amplification (LAMP) Assays for the Species-specific Detection of Eimeria that Infect Chickens
Published on: February 20, 2015