Canonical cytosine base editors (CBEs) achieve precise C-to-T conversions without inducing DNA double-strand breaks (DSBs), yet their clinical potential remains hampered by substantial off-target (OT) mutations. The recently developed transformer base editor (tBE) significantly reduces both genomic and transcriptomic OT mutations by using a cleavable deoxycytidine deaminase inhibitor (dCDI) domain. However, the modest base editing efficiency limits its broader applications. Here, through rational deaminase engineering and fusion of a uracil DNA glycosylase inhibitor (UGI) domain, we developed the engineered tBE (etBE). The etBE exhibited substantially enhanced editing efficiencies compared with the parental tBE (up to 35.11-fold improvement), while maintaining high editing fidelity and background levels of OT mutations. As a therapeutic proof-of-concept, dual adeno-associated virus (AAV)-mediated delivery of etBE targeting proprotein convertase subtilisin/kexin type 9 (PCSK9), a well-established therapeutic target for cardiovascular diseases, was evaluated in a humanized mouse model. The treatment achieved efficient in vivo base editing (up to 35.13%), resulting in substantial reductions in plasma PCSK9 protein (24%) and low-density lipoprotein cholesterol (LDL-C) levels (33%), while inducing only minimal OT mutations. Collectively, etBE represents a highly efficient and specific base editing platform with enormous potential for both basic research and clinical applications.
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Transformers with Off-Nominal Turns Ratios
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Instrument Transformers
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the copper windings...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...