Related Experiment Video
Updated: Sep 13, 2026

Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
Interpreting forearm flexural rigidity from cortical bone mechanics technology under forward-fall loading: A
Brian C Clark1, Leatha A Clark1, Andrew Dick2
1Ohio Musculoskeletal and Neurological Institute, Ohio University, Athens, OH, United States of America; Department of Biomedical Sciences, Heritage College of Osteopathic Medicine, Ohio University, Athens, OH, United States of America; Biomedical Engineering Graduate Program, Russ College of Engineering, Ohio University, Athens, OH, United States of America.
Abstract:
Fractures occur when loads exceed bone capacity. Cortical Bone Mechanics Technology (CBMT) noninvasively assesses ulnar bending and yields flexural rigidity (EI), a mechanical property strongly associated with whole-bone bending strength. No framework places CBMT-reported EI on a fall-demand scale.
Methods:
We developed an illustrative, reduced-order scaling framework to estimate the CBMT-reported EI required for modeled ulnar bending capacity to match bending-equivalent demand across forward-fall-on-an-outstretched-hand (FOOSH) scenarios. This central required-EI estimate was denoted EI₅₀. The model varied body size, surface compliance, upper-extremity compliance, two-hand versus one-hand loading, and effective moment arm.
Results:
Across 324 primary scenarios, EI₅₀ ranged from 11.0 to 66.2 N·m2. Median EI₅₀ doubled from 19.0 N·m2 for symmetric two-hand FOOSH to 38.0 N·m2 for unilateral single-hand FOOSH. For median-body-size older-adult women, EI₅₀ ranged from 14.1 to 22.9 N·m2 for two-hand loading and 28.2-45.7 N·m2 for single-hand loading; corresponding ranges for men were 16.2-26.3 and 32.4-52.6 N·m2. A sensitivity analysis using a published 2.5-4.0 kN standing-fall force envelope yielded wider required-EI ranges of 25.4-50.8 N·m2 for two-hand conditions and 50.8-101.6 N·m2 for single-hand conditions across the prespecified moment arms.
Conclusions:
CBMT EI is a mechanically interpretable forearm cortical phenotype that can be contextualized against explicitly defined fall-demand scenarios. The framework is illustrative and does not estimate site-specific or patient-level fracture probability.
Related Concept Videos
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Applications of Stress
The...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...
Impact Loading
In cases of elastic deformation,...
Euler's Formula to Columns: Problem Solving
The system comprises two vertical rigid bars, AB and BC, of...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity