3-D High-Quality Power Doppler Using Coherence-Based Null Subtraction Imaging
Abstract:
Three-dimensional power Doppler (PD) imaging enables visualization of volumetric microvasculature networks. However, 3-D ultrafast PD imaging with matrix arrays suffers from limited resolution due to the restricted aperture size and the use of unfocused plane waves, while delay-and-sum (DAS) exhibits high sidelobe levels (SLLs) and broad main lobes, hindering high-quality PD imaging. In this study, we aim to improve the 3-D null subtraction imaging (NSI) and propose coherence-based NSI beamformers, including NSI based on coherence factor (NSI-CF) and NSI based on spatial and angular CF (NSI-SACF). Specifically, NSI-SACF integrates the high-resolution capability of NSI and the high-contrast performance of SACF. The proposed beamformers are validated through simulations, phantom experiments, and in vivo experiments. Qualitative and quantitative evaluations confirm the superiority of NSI-SACF. In the simulations, NSI-SACF achieves a full-width at half-maximum (FWHM) of 0.059 mm compared with 0.391 mm for DAS and 0.225 mm for SACF. NSI-SACF also reduces the SLL by 75.5 dB and 33.6 dB compared with DAS and SACF, respectively, while effectively suppressing grating lobes. In the in vivo experiments, NSI-SACF improves the contrast-to-noise ratio (CNR) of blood flow by 20.03 and 8.65 dB over DAS and SACF, respectively. Furthermore, the FWHM of the vessel is reduced to 0.098 mm with NSI-SACF, compared with 0.326 mm for DAS and 0.159 mm for SACF. In summary, the proposed NSI-SACF beamformer effectively enhances the PD imaging by simultaneously improving spatial resolution and contrast, demonstrating the potential for clinical applications.
Related Concept Videos
Doppler Effect - II
Doppler Effect - I
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)