Related Experiment Video
Updated: Sep 16, 2026

Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Prognostic Value of Traditional and Optimised Vital Sign Thresholds for Risk of Serious Adverse Events in
Nikolaj Aagaard1, Markus Harboe Olsen1,2, Jesper Mølgaard3
1Department of Anaesthesia and Intensive Care, Copenhagen University Hospital-Bispebjerg and Frederiksberg, 2400 Copenhagen, Denmark.
Abstract:
Technological advances enable continuous vital sign monitoring with wireless biosensors in general wards. However, traditional thresholds used in routine monitoring do not effectively identify serious adverse events (SAEs). This study aimed to assess the prognostic ability of combinations of threshold severity and duration in continuous vital sign monitoring for SAEs in acute medical and surgical patients. Data on heart rate (HR), respiratory rate (RR), and peripheral oxygen saturation (SpO2) were collected from four prospective observational studies and two randomised controlled trials. The primary outcome was an SAE within 30 days. Traditional thresholds were based on the National Early Warning Score, and optimised thresholds were derived by identifying threshold values and durations with the highest area under the receiver operating characteristic curve (AUROC) for any SAE and specific SAE types. Of 1492 patients, 1077 were included in HR and RR analyses and 761 in SpO2 analyses; 30% experienced an SAE. For any SAE, traditional thresholds had AUROC values of 0.47-0.50 (95% CI 0.43-0.54). Optimised thresholds also showed limited ability (AUROC 0.51, 95% CI 0.44-0.56). In contrast, 18 thresholds for specific SAE types had AUROC > 0.70; the highest AUROC was observed for HR > 104 beats/min for ≥36 min for upcoming respiratory SAEs (AUROC 0.82, 95% CI 0.74-0.90). Optimised thresholds showed low prognostic ability for any SAE but higher AUROC than traditional thresholds. Several thresholds demonstrated moderate prognostic ability for specific SAE groups and warrant validation.
Related Concept Videos
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes or...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Errors occurring during blood pressure monitoring
Several factors...