A Spectral-Emissivity-Corrected Method for Temperature Inversion from CCD Images
Meng Zhao1, Chunyu Liu1, Maoyong Bai1
1Key Laboratory of Spectral Detection Science and Technology, School of Physics, Changchun University of Science and Technology, Changchun 130022, China.
Abstract:
Accurate high-temperature field characterization is important for explosion diagnostics, laser-matter interaction, combustion monitoring, and related thermal processes. This work presents an integrated thermometry framework combining fiber-optic spectrometry with monochrome imaging. Its central contribution is not a new multispectral principle or optimization algorithm, but an integration-time-dependent radiometric calibration framework coupled with representative spectral-emissivity transfer under clearly stated applicability conditions. Its central element is a three-parameter radiometric calibration model in which camera integration time is explicitly included, so that radiance conversion can be performed across the experimentally calibrated integration-time range without repeating a separate fixed-exposure calibration for each setting. Multiwavelength spectral radiance is used to jointly retrieve temperature and a continuous, second-order polynomial emissivity function with a genetic algorithm serving as the global optimizer. The emissivity function obtained from a representative spectral sampling region is then transferred to the imaging model for pixelwise temperature inversion; this step assumes that the material and surface state are sufficiently uniform over the region to which the function is applied. The method is examined using steady-state tungsten-halogen-lamp measurements with nominal color temperatures of 2200-2800 K and a transient laser-heated 316L stainless-steel case. Agreement with a Wien-based estimate is used as an internal spectral-consistency check rather than as an independent traceable accuracy validation. In the transient case, the retrieved spectral-field-of-view temperature increased from 2311.9 to 2398.5 K over 50-60 s, and the reconstructed images reproduced the corresponding increase in the central high-temperature region. The present results demonstrate the feasibility of coupling integration-time-dependent calibration with measured spectral-emissivity transfer for two-dimensional temperature reconstruction, while the achievable absolute accuracy remains subject to detector linearity, emissivity-model validity, spatial emissivity uniformity, radiometric calibration, and independent reference validation.
Related Concept Videos
IR Spectrometers
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Absorption of Radiation