Related Experiment Videos
A Two-Stage Multi-Source Unilateral Alignment Method for Rail Insulation Fault Localization Under Target-Domain
Qiaoyue Li1, Bo Chen2, Guifu Du2
1School of Optical and Electronic Information, Suzhou City University, Suzhou 215104, China.
Abstract:
To address the decline in insulation fault localization accuracy of urban rail DC traction return systems under varying operating conditions and missing target-domain classes, this study proposes a two-stage multi-source unilateral alignment network (MUAN). In practice, different loads and operating conditions lead to different rail-potential patterns, while the target-domain training set often lacks some fault classes. Conventional domain adaptation methods usually assume identical label spaces across domains, which may cause source-private classes to be incorrectly aligned and thus induce negative transfer. To mitigate this issue, a multi-source partial domain adaptation framework is developed. In the first stage, labeled source data from multiple conditions are used to learn discriminative features, and source anchor features are extracted for subsequent transfer. In the second stage, source-alignment and cross-domain alignment modules are introduced to guide the target features toward the shared class space while preserving the source class structure. Domain-adversarial learning is further employed to reduce cross-condition distribution gaps and improve generalization to unlabeled target data with missing classes. Experiments on both a dynamic rail-potential simulation platform and a return-system hardware platform show that the proposed method achieves superior fault localization performance, especially under target-domain missing-class settings.
Related Concept Videos
Fault Types
For line-to-line faults occurring between phases B and C, the...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Power System Three-Phase Short Circuits
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...