Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
A Center-of-Pressure Guided Finger-Press Sensor for Cuffless Blood Pressure Estimation
Farhad Ali Irinel Gul1, Dan Tudose1
1Department of Computer Science and Engineering, Faculty of Automatic Control and Computers, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania.
Abstract:
Cuffless blood pressure estimation using the finger-pressing method remains sensitive to improper finger centering and inconsistent contact force, which degrade the accuracy of the oscillometric envelope and PPG signal morphology. This paper details the development of a research prototype that integrates three force sensors and a photoplethysmograph (PPG) sensor to quantify the finger-device interaction. This system is intended as a pre-clinical research tool rather than a clinically validated medical device. We implement a weighted centroid algorithm for center of pressure (CoP) feedback to guide geometric centering, alongside a Hybrid Ridge Regression model to estimate the total contact force. The system was evaluated on a pre-clinical pilot cohort of 48 healthy participants (1274 recordings), comparing inflationary (ramp-up) and deflationary (ramp-down) interaction modalities. Force calibration achieved a mean absolute error (MAE) of 1.2 g, with hardware analysis confirming a limited zero-load baseline drift of -0.29% over 50 days. The best single-recording calibrated model achieved a mean absolute error (MAE) of 5.55 mmHg (systolic) and 5.20 mmHg (diastolic), with a mean error (ME) ± standard deviation (SD) of +0.50±7.25 and +1.19±6.47 mmHg, respectively, in this pilot cohort, demonstrating the feasibility of the three-point force-sensing design with CoP tracking.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure