Related Experiment Video
Updated: Sep 17, 2026

Coronary Progenitor Cells and Soluble Biomarkers in Cardiovascular Prognosis after Coronary Angioplasty
Published on: January 28, 2020
Circulating Serum AGRN and ADAMTS8 With Related Candidates as Potential Biomarkers for Carotid Plaque Presence and
Shuaiwei Guo1, Shengyan Cui1, Xiao Zhang1
1Department of Neurosurgery, Xuanwu Hospital, China International Neuroscience Institute; Capital Medical University, National Center for Neurological Disorders, Beijing, China.
Background:
Carotid atherosclerosis is a major etiologic substrate for ischemic stroke. Although imaging can characterize stenosis and plaque morphology, circulating biomarkers may better support screening and scalable risk stratification, yet reliable serum protein markers for carotid plaque, particularly for plaque instability, remain limited.
Methods:
We enrolled 128 participants, including patients with stable plaques (n = 41), unstable plaques (n = 49), and healthy controls (n = 38). Plaque stability was determined by carotid ultrasonography. We prespecified a serum biomarker panel comprising seven proteins and measured all of them: agrin (AGRN), ADAMTS8, ADAMTS9, collagen type XVIII alpha 1 chain (COL18A1), integrin subunit beta 4 (ITGB4), lysyl oxidase like 4 (LOXL4), and slit guidance ligand 3 (SLIT3). All proteins were quantified by enzyme-linked immunosorbent assay (ELISA). Group comparisons were performed with multiple-comparison adjustment. Receiver operating characteristic (ROC) analyses and the area under the curve (AUC) evaluated the ability of individual biomarkers and the combined prediction probability to discriminate plaque presence and plaque instability.
Results:
Baseline characteristics differed substantially between plaque groups and healthy controls. Serum AGRN concentrations were significantly elevated in plaque patients versus controls (mean ± SD, Stable: 2222.42 ± 508.30 pg/mL; Unstable: 2109.59 ± 513.51 pg/mL; Healthy: 1800.36 ± 375.89 pg/mL; overall p < 0.001), while ADAMTS8 levels were comparable across groups (overall p = 0.110). In multivariable Firth penalized logistic regression with log2-transformed biomarkers, neither AGRN nor ADAMTS8 was independently associated with plaque presence or plaque instability after adjustment for age, sex, hypertension, alcohol use, dyslipidemia, smoking, diabetes mellitus, and coronary heart disease (all adjusted p > 0.05). For discriminating plaque presence, the combined AGRN+ADAMTS8 model achieved an apparent AUC of 0.771 (bootstrap 95% CI, 0.678-0.865; optimism-corrected AUC, 0.764; repeated stratified 5-fold cross-validated AUC, 0.749). For plaque instability, the combined model showed no discriminatory capacity (apparent AUC, 0.549; optimism-corrected AUC, 0.498; repeated 5-fold cross-validated AUC, 0.471).
Conclusions:
Circulating AGRN and ADAMTS8, measured as serum concentrations, are associated with carotid plaque presence versus healthy controls but do not independently discriminate plaque presence or instability after multivariable adjustment. Clinical covariates alone (age, sex, vascular risk factors) provided near-perfect discrimination of plaque presence, indicating substantial spectrum bias arising from the healthy-control comparator design. These findings underscore the need for age- and risk-matched comparator populations in future biomarker studies, consistent with STARD 2015 recommendations.
Related Concept Videos
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...