Related Experiment Video
Updated: Sep 19, 2026

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Ocular temperature measured by infrared thermography in dogs varies with biological and environmental factors
Sahar Rostami1, Kimberly A Woodruff1, Abigail McBride1
1Department of Pathobiology and Population Medicine, College of Veterinary Medicine, Mississippi State University, Starkville, MS, United States.
Abstract:
Non-contact temperature assessment is highly valuable for screening animal populations, but its performance can be influenced by various external and biological variables. This study aimed to quantify the association between eye temperature (ET) and rectal temperature (RT) in dogs, and to identify physiological and environmental factors associated with these readings. Field study: ET was obtained with a thermal camera up to 3 times per visit (~10-min intervals), followed by RT measurement. Eye temperature was defined as the highest temperature recorded from either eye. A linear mixed-effects model evaluated ET in relation to capture time (1-3), RT, age, sex, body size, coat length, ambient temperature, and relative humidity. Device temporal stability assessment: To account for potential camera drift observed in our previous research, temperature at a fixed target inside an insulated box was recorded every 5 min for 1 h and analyzed with repeated-measures mixed model regression. Results. We analyzed 129 observations from 78 dogs. In the final ET model, both RT (β = 0.77 °C; 95% C.I. 0.512-1.019 °C) and humidity (β = 0.01 °C; 95% C.I. 0.002-0.013 °C) were positively and significantly associated with ET. The device stability assessment demonstrated no significant time-related measurement drift. Overall, ET was associated with RT but was not interchangeable and ET was slightly affected by environmental humidity. These results support further investigation of using ET as a rapid, noncontact temperature monitoring procedure.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Body Temperature
Factors Affecting Body Temperature
Factors may include:
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Thermosensation

