Related Experiment Video
Updated: Sep 19, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Assessing Inter-rater Reliability and Intra-rater Reliability During the 2-Minute Hand-Release Push-Up Event in the
Drew Van Dam1, Rachel Gidaro2, Sarah Ferreira1
1Department of Physical Education, United States Military Academy @ West Point, West Point, New York.
Abstract:
Van Dam, D, Gidaro, R, Ferreira, S, Morogiello, J, Jaffe, D, and Semmel, A. Assessing inter-rater reliability and intra-rater reliability during the 2-minute hand-release push-up event in the army fitness test. J Strength Cond Res XX(X): 000-000, 2026-The Army Fitness Test, implemented in 2025, assesses soldier readiness via 5 physically challenging events (3 repetition maximum deadlift, hand-release push-up, sprint-drag-carry, plank, and 2-mile run). Each event is graded by individuals with varying levels of experience, thus posing a threat to the reliability of the physical performance scores. The purpose of this study was to examine the inter-rater and intra-rater reliability of the two-minute hand-release push-up test to facilitate learning and improvement of assessing physical performance. Seventeen raters (5 female, 12 male) graded 10 hand-release push-up (HRPU) videos over 3 separate weeks (30 total videos, 60 total minutes). Each video contained a recording of a Cadet performing the two-minute HRPU test. Raters were required to provide a response after each repetition by stating "yes" for a proper repetition and "no" for an improper repetition. Researchers recorded all responses from raters in each of the 3 settings. Videos were randomized for each week of viewing with no rater viewing the videos in the same order. Using a logistic model, we were able to measure inter-rater and intra-rater reliability. Researchers calculated the intraclass correlation coefficient to evaluate overall reliability and agreement and Prevalence-Adjusted, Bias-Adjusted Kappa to further understand inter-rater and intra-rater reliability. Ultimately, we found that raters were not consistent as a group, with some showing significant fluctuations in their responses between tests. This finding is crucial because even small differences in scoring can negatively impact assessment on the HRPU event influencing a subjects's total score.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

