Related Experiment Video
Updated: Sep 20, 2026

Standardized Protocol For Monitoring Muscle Fatigue and Biomechanics In Amateur Cyclists Using Infrared Thermography
Published on: March 20, 2026
Monitoring core temperature, match running characteristics and performance indicators during professional football in
J D Périard1, H A Brown2, J K Mara3
1Research Institute for Sport and Exercise (UCRISE), University of Canberra, Australia.
Objectives:
To explore associations between environmental conditions, core temperature and running characteristics during 2024-2025 A-League Men's (ALM) and Women's (ALW) matches.
Design:
Longitudinal cohort study.
Methods:
Gastrointestinal temperature (Tgi) and match running characteristics were recorded on 100 occasions in seven ALM (n = 35) and 20 ALW (n = 65) players across 11 and 13 matches, respectively. Environmental conditions, including wet-bulb globe temperature (WBGT), were measured in all matches.
Results:
Average match conditions were 27.1 °C, 57% relative humidity and 22.7 °C WBGT for ALM, and 29.4 °C, 48% relative humidity and 24.7 °C WBGT for ALW (P ≥ 0.18). Mean peak Tgi in ALM (39.4 °C [39.2, 39.7]) was significantly higher than in ALW (39.1 °C [38.9, 39.2]; P = 0.03). Tgi exceeded 40 °C on seven occasions in six players (3 ALM, 3 ALW) with highest values of 40.8 °C (ALM) and 40.1 °C (ALW). Mean total running distance for players who completed ≥90 min of match play was 10,879 m [10,124, 11,634] for ALM and 10,500 m [10,047, 10,954] for ALW (P = 0.38). Distance covered at high intensity was 679 m [480, 879] for ALM and 485 m [366, 604] for ALW (P = 0.10). A 1 °C rise in WBGT was associated with an increase in peak Tgi in ALM (0.05 °C [0.02, 0.09], P < 0.01) but not ALW (0.0 °C [-0.03, 0.05], P = 0.56) and had no association with running characteristics.
Conclusions:
Professional footballers experience considerable thermal strain during competitive match play across different environmental conditions. Given the absence of any meaningful association of WBGT with peak Tgi and running characteristics, alternative methods to quantify heat illness risk in professional football should be explored.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...