Related Experiment Video
Updated: Sep 22, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Short- and Long-Term Outcomes After Transcatheter Aortic Valve Implantation With Large Self-Expanding Valves
Polyxeni Alexiou1, Federico Moccetti1, Stephanie Brunner1
1Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.
Background:
Patients with large aortic annuli are a more challenging subgroup for transcatheter aortic valve implantation (TAVI), and data on long-term outcomes are sparse.
Aims:
Compare outcomes of patients with large annular anatomies to outcomes of patients with regular anatomies.
Methods:
Between January 2015 and November 2025, 488 patients underwent TAVI with different generations of Evolut valves for the treatment of native aortic stenosis. Outcomes of large 34 mm valves were compared to regular size 23-29 mm valves. To account for the nonrandomized design, the primary comparison was performed in a 1:1 propensity score matching cohort.
Results:
A total of 186 (38%) patients received large and 302 (62%) received regular size valves. Propensity score matching yielded 141 well-balanced pairs, in whom age (80 ± 6 vs. 81 ± 6 years), STS-PROM score (3.2 [2.0-4.9] vs. 3.6 [2.1-5.8]), and male sex (96% vs. 97%), were comparable. Procedural technical success (95% vs. 94%), device success (90% vs. 92%), and early safety (79% vs. 79%) were comparable. At 30 days, mortality (2.1% vs. 1.4%), stroke (2.1% vs. 3.5%), and new pacemaker implantation (12% vs. 11%) did not differ significantly. At 5 years, there were no significant differences between the groups in all-cause mortality (HR 1.06, 95% CI 0.64-1.76, p = 0.8), stroke (sHR 0.74, 95% CI 0.26-2.11, p = 0.6), heart failure rehospitalization (sHR 0.96, 95% CI 0.46-2.01, p=0.9), or new pacemaker implantation (sHR 1.02, 95% CI 0.57-1.82, p = 0.9). Structural valve deterioration stage 3 (0% vs. 1.6%), infective endocarditis (1.7% vs. 2.8%), and valve reintervention (0% vs. 0.9%) were infrequent in both groups. The findings were consistent in the whole-cohort analysis.
Conclusion:
Outcomes after TAVI with large self-expanding valves were comparable to regular size valves, demonstrating favorable results up to 5 years of follow-up.