Randomized Evaluation of a Textile-Based Enhanced Radiation Protection Device Versus Control Shielding in the Cardiac
Oskar Angerås1,2, Pernilla I Jonasson3,4, Christian Dworeck1,2
1Department of Molecular and Clinical Medicine, Institute of Medicine, University of Gothenburg, Gothenburg, Sweden.
Background:
Occupational radiation exposure remains an inherent risk in cardiac catheterization laboratories. Conventional radiation protection relies on ceiling- and table-mounted shields combined with wearable lead-equivalent personal protective equipment, yet exposure persists and ergonomic burden remains substantial. Enhanced radiation protection devices (ERPD) aim to attenuate scatter radiation at the patient level, but randomized evaluations using comprehensive dosimetry are limited.
Methods:
In this prospective, single-center, cluster-randomized study, shielding strategies were alternated by week (6 ERPD vs 6 control weeks). A textile-based ERPD (Texray MasterPeace™) was compared with control shielding. Occupational radiation exposure to the first operator and scrub nurse was assessed using a 69-point thermoluminescent dosimetry array worn over personal protective equipment, capturing deep dose equivalent (Hp(10) for operator and scrub nurse roles. The primary end point was weekly cumulative Hp(10) normalized to patient radiation output. Secondary analyses included spatial dose distribution and accumulated Hp(10) over the study period.
Results:
A total of 190 procedures were included (ERPD n = 90; control n = 100). Baseline procedural characteristics, including dose area product and fluoroscopy time, were similar between groups. Mean weekly operator Hp(10) was 0.11 mSv with conventional shielding and 0.02 mSv with ERPD (mean difference -0.083 mSv; 95% CI -0.106 to -0.061; P < .001), corresponding to an 78% relative reduction. Scrub nurse exposure was similarly reduced (0.06 vs 0.01 mSv; 77% reduction). Findings were consistent with reductions across all anatomical regions.
Conclusions:
In a randomized real-world setting, MasterPeace ERPD substantially reduced occupational radiation exposure for both operators and scrub nurses, supporting its use as an adjunct to conventional shielding.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization III: Left Heart Catheterization
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...