Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Extra-Large Blood Pressure Cuff Need and Cost Burden in United States Adults with Hypertension
Sumit Sahoo1, Tammy Brady2,3, Benjamin Grobman4
1Northeastern University, Boston, MA.
Background:
Accurate home blood pressure (BP) monitoring depends on appropriate cuff sizing, but the prevalence and cost implications of extra-large cuff need among US adults with hypertension are unknown.
Methods:
Using pooled data from 2017-2023 National Health and Nutrition Examination Survey (NHANES) with survey weighting, we estimated the prevalence of having a mid-arm circumference >43cm among US adults with hypertension, overall and by race/ethnicity. We also categorized home BP monitors listed on the US Validated Device Listing as standard (accommodating arm circumferences from 22-43cm) or extra-large cuff compatible (accommodating arm circumferences >43cm).
Results:
Approximately 6.6% of US adults with hypertension (∼ 7.2 million individuals) had an arm circumference >43cm. Prevalence was highest among Non-Hispanic (NH) Black adults (11.4%) followed by Other Race/Multiracial (8.2%), NH White (6.2%), Hispanic (5.3%) and NH Asian adults (0.9%). Of the 51 validated devices, only 22 (43.1%) accommodated arm circumferences >43cm. The mean total cost of an extra-large cuff compatible system was 32.7% higher ($99.06 versus $74.70 for standard devices).
Conclusions:
More than 7 million US adults with hypertension require an extra-large BP cuff; the substantially higher cost of extra-large cuff-compatible devices represents an important and underrecognized barrier to accurate home BP monitoring.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...