Electrocardiographic Identification and Correction of Left Ventricular Pacing Latency
T R Muralidharan1, D R Nivetha1, S Sanjith1
1Department of Cardiology, SRM Medical College Hospital and Research Centre, Faculty of Medicine and Health Sciences, SRM Institute of Science Technology, Kattankulathur, Chengalpattu, Tamil Nadu, India.
Abstract:
Pacing latency, defined as the delay between a pacemaker stimulus and myocardial depolarization, is an uncommon but clinically relevant phenomenon in patients with permanent pacing systems. Its presence may be mistaken for a lead malfunction, exit block, or device failure, leading to unnecessary interventions. A 55-year-old male with a history of nonischemic dilated cardiomyopathy (left ventricular [LV] ejection fraction-30% on standard two-dimensional echocardiography; 17% on speckle-tracking assessment) and severe systolic dysfunction, previously implanted with a cardiac resynchronization therapy with defibrillator (CRT-D), was admitted with progressive abdominal distension, bilateral lower limb edema, and weight gain of 5-6 kg over 2 weeks. Examination revealed hypotension (90/60 mmHg), elevated jugular venous pressure, pedal edema, and basal crepitations. Laboratory evaluation showed elevated N-terminal pro-B-type natriuretic peptide (4750 pg/mL). He was treated with intravenous diuretics and guideline-directed medical therapy, resulting in clinical improvement and weight reduction from 75 to 70 kg. During hospitalization, device interrogation confirmed stable parameters. However, a 12-lead electrocardiography demonstrated consistent pacing latency with an 80 ms delay between the pacing spike and QRS onset. Electrolytes were normal, and no offending medications were identified. The patient was discharged in New York Heart Association Functional Class II after symptomatic improvement. This case highlights the mechanical and electrophysiological consequences of LV pacing latency in a patient with CRT-D and worsening heart failure. Pacing latency required active correction to restore effective biventricular resynchronization. Recognition of this entity is essential to guide targeted device optimization and prevent unnecessary interventions. Advanced echocardiographic techniques play a critical complementary role in assessing the mechanical impact of pacing latency and the efficacy of its correction.
More Related Videos
09:52Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias IV: Characteristics of Bradyarrhythmias