First-Trimester Assessment of the Extended Fetal Cardiovascular System Using the CASSEAL 3 × 3 Framework:
Cristina Martínez Payo1,2,3, Irene García Nieto1,2,3, Ana Jimena Salcedo Martínez1,2,3
1Department of Public and Maternal and Child Health, Faculty of Medicine and Health Science, School of Medicine, Complutense University of Madrid, 28040 Madrid, Spain.
Background:
The Extended Fetal Cardiovascular System (EFCS) encompasses the cardiac, infracardiac, and supracardiac vascular territories that contribute to fetal cardiovascular development and function. The CASSEAL 3 × 3 framework was developed to provide a structured anatomical assessment of the EFCS. This study aimed to evaluate its feasibility, reproducibility, and diagnostic performance during first-trimester screening.
Methods:
In this prospective single-center study, singleton pregnancies undergoing ultrasound examination between 11 + 0 and 13 + 6 weeks of gestation were assessed using the CASSEAL 3 × 3 framework. Feasibility, examination time, use of complementary techniques, interobserver reproducibility, and diagnostic performance were evaluated. Prenatal follow-up and postnatal findings served as the reference standard.
Results:
A total of 288 pregnancies were included in the final analysis. Complete visualization of all nine axial views was achieved in 86.5% of examinations. Mean examination time was 12.5 ± 3.3 min. Higher gestational age increased the likelihood of complete visualization, whereas higher maternal body mass index reduced feasibility. Interobserver agreement was high, with no significant systematic differences between operators. Six suspected EFCS abnormalities were identified during first-trimester examination. Diagnostic performance demonstrated high specificity (99.64%) and negative predictive value (98.58%), whereas sensitivity was moderate and should be interpreted cautiously due to the limited number of confirmed abnormalities.
Conclusions:
The CASSEAL 3 × 3 framework is a feasible and reproducible approach for structured first-trimester assessment of the EFCS. Diagnostic performance estimates should be interpreted cautiously given the limited number and spectrum of confirmed abnormalities and the use of a composite reference standard without systematic postnatal echocardiography. The framework may be better suited to specialized fetal medicine settings or as an adjunct to routine first-trimester assessment rather than as a universal screening tool.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...