Importance:
Children undergoing tracheostomy have heterogeneous clinical profiles, yet no scalable, tracheostomy-specific system exists to stratify risk using administrative data. General severity measures such as All Patient Refined Diagnosis Related Group (APR-DRG) provide limited case mix differentiation for this population.
Objective:
To evaluate whether a literature-derived, tracheostomy-specific risk-tier system improves stratification of pediatric index hospitalization outcomes compared with APR-DRG severity classification.
Design, Setting, And Participants:
In this retrospective cohort study using the Pediatric Health Information System database, participants were children younger than 18 years undergoing index tracheostomy placement at 44 tertiary children's hospitals from January 1, 2016, through December 31, 2024, in the US.
Main Outcomes And Measures:
The primary outcomes were prolonged length of stay (greater than 90 days) and in-hospital mortality. Risk stratification was assessed by separation of outcomes across proposed tiers (standard, moderate, or critical risk) and supported by discrimination metrics (C statistics).
Results:
Among 14 275 patients (6027 female [42.2%]; 8237 male [57.7%]; median [IQR] age, 0 [0-7] years), 3431 (24%) were in the critical-risk tier, 9363 (66%) in the moderate-risk tier, and 1481 (10%) in the standard-risk tier. The median (IQR) length of stay increased from 34 (16-69) days (standard-risk tier) to 105 (54-192) days (moderate-risk tier) to 173 (104-263) days (critical-risk tier). Mortality increased from 70 (4.7%) in the standard-risk tier to 710 (7.6%) in the moderate-risk tier to 554 (16.1%) in the critical-risk tier. The tier system C statistic was 0.665 (95% CI, 0.658-0.672) for prolonged hospitalization and 0.608 (95% CI, 0.594-0.622) for mortality, compared with 0.521 (95% CI, 0.519-0.524) and 0.509 (95% CI, 0.507-0.511) for APR-DRG. Intraclass correlation coefficients were 0.065 (95% CI, -0.214 to 0.335) for prolonged stay and 0.005 (95% CI, -0.001 to 0.011) for mortality. The intraclass coefficient is bounded at 0. The negative lower limit reflects the Wald approximation for a variance component estimated near zero, not a genuinely negative correlation, consistent with negligible between-hospital variance.
Conclusions And Relevance:
In this cohort study, a tracheostomy-specific risk-tier system using administrative data provides meaningful case mix stratification for pediatric tracheostomy hospitalizations and outperforms general severity classification. This approach may support risk-adjusted benchmarking and multicenter comparisons, though modest discrimination limits individual-level prognostic use and warrants further validation.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...