Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

    The European Physical Journal. C, Particles and Fields
    |September 25, 2026
    PubMed

    Related Concept Videos

    Atomic Emission Spectroscopy: Overview01:20

    Atomic Emission Spectroscopy: Overview

    Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
    Atomic Emission Spectroscopy: Lab01:29

    Atomic Emission Spectroscopy: Lab

    AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
    Atomic Emission Spectroscopy: Instrumentation01:22

    Atomic Emission Spectroscopy: Instrumentation

    The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
    Double Resonance Techniques: Overview01:12

    Double Resonance Techniques: Overview

    Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
    Spin decoupling is usually achieved by...
    Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

    Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

    In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
    Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

    Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

    Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
    The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...