Catalyst-directed vibrational frequency disparity for isotopologue sieving in CO2 electrolysis

Ningce Zhang1, Haoyun Bai1, Guoqiang Shen1

  • 1State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Hunan University, Changsha, China.

Nature Chemistry
|September 25, 2026
PubMed

Related Concept Videos

¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
π Electron Effects on Chemical Shift: Overview01:27

π Electron Effects on Chemical Shift: Overview

An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0, resulting in...
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...