Related Experiment Video
Updated: Sep 27, 2026

Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Patient-Specific Computational Fluid Dynamics of Pulmonary Arterial Hemodynamics in Dogs with and Without Pulmonic
Carla Zamora-Perarnau1,2,3, Mauro Malvè4,5,6, Patricia Sebastián-Marcos2,3
1Doctoral School, Catholic University of Valencia San Vicente Mártir, San Agustín Square, 3, 46002 Valencia, Spain.
Abstract:
Pulmonic stenosis (PS) is one of the most common congenital cardiac diseases in dogs. Although echocardiography and computed tomographic angiography (CTA) provide valuable diagnostic and anatomical information, the hemodynamic consequences of PS remain incompletely characterized. This study describes patient-specific pulmonary artery hemodynamics in dogs with and without PS using computational fluid dynamics (CFD). Contrast-enhanced CTA and echocardiographic data from five dogs with PS and five control dogs without PS were used to reconstruct three-dimensional pulmonary artery geometries and generate patient-specific CFD models. Pressure drop (Δp), blood flow velocity, mean wall shear stress (WSS), time-averaged WSS (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and pulmonary artery resistance were quantified and compared between groups. Dogs with PS exhibited markedly increased transvalvular pressure gradients, peak flow velocities, and pulmonary artery resistance, together with high-velocity jets and localized post-stenotic recirculation that were absent in control dogs. Mean WSS and TAWSS tended to be higher in the PS group, whereas OSI values were similar between groups. In contrast, RRT was significantly lower (p = 0.032) in dogs with PS. These findings demonstrate that patient-specific CFD enables detailed characterization of pulmonary artery hemodynamics in canine PS, providing information that complements conventional imaging. Although its clinical utility in veterinary medicine has yet to be fully established, CFD can provide valuable insight into flow behavior and disease pathophysiology; however, its ability to yield precise, clinically applicable quantitative values remains limited. This approach shows promise for future applications in the clinical evaluation of PS and other cardiovascular diseases, although further studies are warranted to determine its clinical relevance in veterinary medicine.
More Related Videos
09:23Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018