Related Experiment Video
Updated: Sep 27, 2026

Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023
The Structure-Function Link of Ellipsoid Zone Integrity and Outer Retinal Features with Visual Acuity in Dry AMD
Reem Amine1,2, Masaharu Mizuno1,2, Karen Matar1,2
1The Tony and Leona Campane Center for Excellence in Image-Guided Surgery and Advanced Imaging Research, Cleveland Clinic, Cleveland, OH 44195, USA.
Abstract:
Background/Objectives: The purpose of this study was to evaluate associations between quantitative ellipsoid zone (EZ) integrity metrics derived from spectral-domain OCT (SD-OCT) and visual outcomes, including clinically meaningful visual acuity (VA) loss, in dry age-related macular degeneration (AMD). Methods: This single-center retrospective image-analysis cohort included 351 eyes from 351 patients with intermediate AMD or atrophic changes. Macular SD-OCT scans were analyzed using a certified-reader-validated machine learning-based segmentation platform to delineate the EZ, retinal pigment epithelium (RPE), and Bruch's membrane (BM). EZ metrics included EZ-RPE thickness (i.e., outer segment thickness) and EZ attenuation, defined as partial attenuation (EZ-RPE thickness of ≤20 µm, abnormal outer segment thinning)) or total attenuation/loss (0 µm). Drusen volume was quantified from the RPE-BM compartment. VA was converted to ETDRS letters. Associations between baseline OCT metrics and baseline VA, Year 2 VA, and ≥15-letter VA loss were assessed using nonparametric testing, linear regression, and ANCOVA. Results: Greater EZ-RPE thickness and lower EZ attenuation were associated with better baseline VA (all p < 0.001), and EZ metrics remained significant in cross-sectional regression models. Among 188 eyes with Year 2 follow-up, 38 (20%) experienced ≥15-letter VA loss. These eyes had significantly lower baseline EZ-RPE thickness (i.e., abnormal outer segment thinning) and greater EZ attenuation than eyes without such loss (all p < 0.001). In ANCOVA models, EZ metrics remained associated with Year 2 VA (all p < 0.001), whereas drusen volume was not. Conclusions: Quantitative EZ integrity metrics were associated with cross-sectional and longitudinal visual outcomes in dry AMD. EZ-RPE thickness and EZ attenuation may serve as clinically relevant OCT biomarkers reflecting photoreceptor integrity and risk of meaningful VA loss.
Related Concept Videos
Anatomy of the Eyeball
Accessory Structures of the Eye
Photoreceptors and Visual Pathways
Glaucoma: Overview

