Abstract:
Waste calcareous opoka rock (WCOR) was investigated as a mass-based replacement for 0.5-1.5 mm granulated dolomite aggregate in thin-layer silicate and mineral renders intended for external thermal insulation composite systems (ETICS). Eight formulations with replacement levels ranging from 0% to 100% were evaluated in terms of fresh-state properties, moisture transport, adhesion, freeze-thaw and sodium sulphate crystallisation resistance, and microstructure using SEM/EDS. Increasing WCOR content reduced fresh-mixture density and flow diameter while increasing resistance to manual surface texturing. In silicate renders, capillary water absorption decreased by 84%, from 1.55 kg/(m2·24 h) for the WCOR-free reference to 0.25 kg/(m2·24 h) at 75% replacement. Conversely, in mineral renders, it increased by 52%, from 17.2 to 26.2 kg/(m2·24 h) at complete replacement. At 100% replacement, freeze-thaw resistance increased from 150 to 308 cycles in silicate renders and from 105 to 251 cycles in mineral renders, while salt-crystallisation resistance increased from 25 to 52 and from 16 to 52 cycles, respectively. Adhesion increased from 0.27 to 0.30 N/mm2 in silicate renders but decreased from 0.31 to 0.19 N/mm2 in mineral renders. SEM/EDS showed matrix-dependent differences in local morphology and aggregate-binder interfaces. Multi-criteria assessment identified 75% replacement as the most balanced option for silicate renders, whereas 25-50% provided the preferred compromise for mineral renders. Overall, the influence and preferred content of WCOR were strongly matrix-dependent.
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Unsoundness of Aggregate due to Volume Change
Permeability of Concrete
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of entrained...
Mortar Properties
Soundness of Cement