Multi-Functional Performance of Upcycled High-Density Polyurethane Floor Fillers in Multi-Story RC Buildings: A
1Department of Civil Engineering, Doğuş University, İstanbul 34775, Türkiye.
Abstract:
This study investigates upcycled high-density polyurethane (HD-PUR) as a substitute for conventional cement-based screed in multi-story reinforced concrete (RC) buildings. Conventional screed (≈2400 kg/m3) adds substantial seismic dead mass without contributing to lateral stiffness, amplifying base shear, inter-story drift, and overturning moments. HD-PUR, produced from industrial waste via mechanical re-pressing, has a density of ≈150 kg/m3 and thermal conductivity of 0.025 W/m·K. It is crucial to clarify that this yields a 16-fold mass reduction specifically at the floor-screed layer level (dropping from 120 kg/m2 to 7.5 kg/m2). Consequently, this localized weight saving translates to an approximately 16.6% reduction in the total seismic weight (W) of the entire building. This substitution also provides near-negligible inter-story heat transfer. Three-dimensional finite element models of 5-, 10-, and 15-story moment-resisting RC frames were developed in SAP2000, with modal and response spectrum analyses performed per the Turkish Building Earthquake Code (TBEC, 2018). HD-PUR substitution reduced base shear by 10.5-20.0% and inter-story drift by 10.4-20.2% across all models. These trends were validated against an existing five-story RC building in Beyoğlu, Istanbul (site class ZC; PGA = 0.359 g; in situ concrete class C14), modeled in SAP2000 and STA. The fundamental period shortened from 0.888 s to 0.793 s, global base shear (FX) decreased by 10.5%, vertical base reaction (FZ) decreased by 16.6%, and the nonlinear pushover-based performance level improved from Collapse Prevention to Life Safety without any intervention on load-bearing members. Thermal calculations per TS 825 indicate an 18% reduction in the heating degree-day load associated with the floor-slab envelope interfaces (basement ceilings and roof slabs), while life-cycle assessment data reported in the literature point to appreciably lower embodied carbon, supporting circular economy objectives. In short, HD-PUR floor fillers offer a low-cost strategy that jointly improves seismic resilience, energy efficiency, and environmental performance in multi-story RC buildings.
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground cistern.
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Fiber Reinforced Concrete
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200 feet...
Superplasticizers
Masonry Loadbearing Walls