Abstract:
Electromagnetic vibration and noise issues of converter transformers under harmonic operating conditions have become increasingly prominent. To enable a systematic comparison of different filtering strategies, this paper establishes a multiphysical field coupling model incorporating electromagnetic, structural, and acoustic fields, and systematically investigates four filtering configurations: grid-side LC filtering, valve-side LC filtering, inductive filtering, and valve-side capacitive filtering through theoretical analysis, finite-element simulation, and experimental verification on a 12-pulse laboratory HVDC prototype platform. The simulation results show that the maximum vibration acceleration decreases from 3.06 m/s2 under the no-filter condition to 1.02 m/s2 under valve-side capacitive filtering. Experimental measurements further confirm the suppression effect, with the vibration acceleration at Point 8 decreasing from 2.28 m/s2 to 0.42 m/s2, corresponding to a reduction of approximately 82%, while the average A-weighted sound pressure level decreases from 66.1 dB to 58.1 dB. These results indicate that vibration and noise suppression cannot be evaluated solely by total harmonic distortion; the attenuation and distribution of individual harmonic components should also be considered. The findings provide a theoretical and engineering basis for the vibration and noise reduction design of converter transformers.
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the copper windings...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The winding...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Instrument Transformers
Transformers with Off-Nominal Turns Ratios