Related Experiment Video
Updated: Oct 2, 2026

Continuous Measurement of Biological Noise in Escherichia Coli Using Time-lapse Microscopy
Published on: April 27, 2021
Correlated Noise Reduction in a CMOS ECG Amplifier: Opportunities and Limitations
Riccardo Olivieri1, Giorgio Tatangelo1, Mehran Khanehbeygi1
1Department of Industrial and Information Engineering and Economics, University of L'Aquila, 67100 L'Aquila, Italy.
Abstract:
Low-noise front-end amplifiers are essential for the acquisition of weak biopotential signals, such as electrocardiograms (ECGs), where the noise introduced by the first amplification stage directly limits the overall signal quality. While correlated noise-cancellation techniques have been extensively investigated for radio-frequency (RF) low-noise amplifiers, their application to low-frequency biomedical interfaces remains largely unexplored because of the different dominant noise mechanisms. This work investigates the applicability of an RF-inspired correlated noise-cancellation methodology to a low-frequency CMOS biomedical preamplifier core intended for ECG front-end applications. The proposed architecture extends a conventional resistive-feedback common-source amplifier by introducing an auxiliary feedforward path designed to attenuate the internally generated correlated noise components without significantly affecting the useful signal. The amplifier was designed in a 150 nm CMOS process and evaluated through AC, noise, Monte Carlo, PVT and time-domain analyses. Compared with the reference single-stage implementation, the proposed architecture achieves approximately a 20% reduction in integrated input-referred noise and a 14% reduction in integrated output-referred noise while marginally improving the voltage gain. Statistical analyses confirm that the proposed technique maintains its effectiveness under process, voltage, temperature, and mismatch variations. Time-domain evaluations with representative ECG waveforms further validate the methodology at the amplifier-core level and indicate its potential integration into complete low-noise biomedical analog front-ends.
More Related Videos
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
Operational Amplifiers
Second-order Op Amp Circuits
The analysis of such circuits follows a systematic approach, similar to the second-order RLC circuits. In practical scenarios, bulky inductors are rarely employed due to their size and weight. This means...
Inverting and Non-inverting OpAmps