A Simple Hump Measuring Technique in Rhinoplasty: A Prospective Study on Precision and Patient Outcomes
Amr Nabil Rabie1, Ahmed Yehia Hussein1,2, Mena Maher Nassif1
1Department of Otolaryngology - Head and Neck Surgery, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
Objectives:
An aesthetically pleasing nasal side profile is a must for a successful rhinoplasty result. We offer a simple technique for accurate measurement of the desired reduction limit of the nasal hump and thus avoiding over- or under-reduction, plus obtaining a single long piece of cartilage that can be used as a graft in the operation.
Methods:
A prospective randomized intervention study compared 20 patients: group A (conventional hump reduction) versus group B (tool-assisted reduction). Outcomes were assessed via Likert scales (1-5) at 6 weeks, 3 months, and 6 months postoperatively.
Results:
Group B showed significantly higher median satisfaction scores for hump reduction (p = 0.006 at 6 weeks, p = 0.003 at 6 months) and overall rhinoplasty outcomes (p < 0.001). The tool enabled precise resection while preserving cartilage for grafts.
Conclusions:
This technique improves reproducibility and patient satisfaction, offering a cost-effective alternative to three-dimensional imaging/artificial intelligence planning.