Point-of-Care Lung Ultrasound in Adults: Image Acquisition
Published on: March 3, 2023
Assessment of pleural effusion using intracavitary contrast-enhanced ultrasound: a pilot study
Dachuan Tang1, Dan Wang1, Zhongyu Li1
1Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Objectives:
To address the limitations of current imaging modalities, the present study aimed to develop and validate a novel intracavitary contrast-enhanced ultrasound (CEUS) approach for the quantitative assessment of pleural effusion (PE) volume and differentiation of exudative PE from transudative PE.
Methods:
This cross-sectional diagnostic accuracy study prospectively enrolled 100 patients with PE undergoing US-guided thoracentesis. Intracavitary CEUS was performed using SonoVue microbubbles, and time-intensity curve parameters (A, B, and A+B) were analyzed. PE volume was measured based on the drainage volume, and effusions were classified as exudates or transudates according to Light's criteria. Diagnostic performance was assessed by receiver operating characteristic (ROC) analysis, and a linear regression model was developed to predict PE volume.
Results:
Exudative PE showed significantly higher baseline intensity parameter B (-35.18 ± 5.17 vs. -41.41 ± 8.64, p < 0.01) and lower peak intensity increment parameter A (1.20 ± 3.27 vs. 6.61 ± 6.10, p < 0.01) compared to transudative PE. The combined parameter A+B (steady-state microbubble concentration index) showed a strong correlation with PE volume (r = 0.912, R 2 = 0.831), yielding the predictive model: V(mL) = -33.345 × (A+B) - 453.071 (intraclass correlation coefficient = 0.950). The ROC analysis revealed moderate diagnostic accuracy for the A value (area under the curve (AUC) = 0.779) and B value (AUC = 0.719) in differentiating exudative PE from transudative PE.
Conclusion:
Intracavitary CEUS could serve as a reliable, minimally invasive, feasible radiation-free adjunctive technique for quantifying PE volume and differentiating exudative versus transudative PE in patients undergoing thoracentesis. The A+B-based regression model provides high predictive accuracy, while A and B values facilitate effusion classification. This quantitative CEUS workflow may facilitate clinical decision-making, and its utility for serial monitoring requires further verification in large-scale real-world cohorts.
More Related Videos
07:59Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
08:22The Application of Point-of-Care Ultrasonography (POCUS) in the Management of Acute Respiratory Distress Syndrome (ARDS) in the Intensive Care Unit
Published on: December 12, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's criteria,...
Imaging Studies II: Ultrasonography