Abstract:
This study assesses machine-learning approaches to predict core temperature (Tc) in workers wearing high-level personal protective equipment (PPE), hypothesizing improved accuracy over conventional methods.
Methods:
Fifty participants (48 male, 2 female) performed exercise protocols while wearing high-level PPE in one of two conditions (NORM [n = 14]: 25-26°C, 45% humidity, HYPR [n = 36]: 35-36°C, 45-50% humidity). The variables collected were skin temperature (Tsk), heart rate (HR), time, respiratory rate (RR), and rate of skin temperature acquisition per minute (Tsk/min). A total of 4063 data points were utilized in two separate, complementary supervised machine learning analyses (random forest [RF] and generalized additive models [GAM]). Model performance was evaluated using both leave-one-subject-out (LOSO) cross-validation and an observation-level 80/20 split (80/20). The two models' performance was measured using adjusted R2, bias, limits of agreement (LoA), root mean squared error (RMSE), mean absolute error (MAE), and standard error of the estimate (SEE).
Results:
LOSO approach: GAM model (R2 of 0.84, a bias of 0.00, a 95% LoA [-0.50°C, 0.50°C], an RMSE of 0.26°C, an MAE of 0.21°C, and a SEE of 0.26°C), RF model (R2 of 0.84, a bias of 0.01, a 95% LoA [-0.50°C, 0.50°C], an RMSE of 0.26°C, an MAE of 0.20°C, and a SEE of 0.26°C). 80/20 approach: GAM model (R2 of 0.89, a bias of 0.00, a 95% LoA [-0.41°C, 0.41°C], an RMSE of 0.21°C, an MAE of 0.17°C, and a SEE of 0.21°C), RF model (R2 of 0.96, a bias of 0.00, a 95% LoA [-0.26°C, 0.26°C], an RMSE of 0.13°C, an MAE of 0.09°C, and a SEE of 0.21°C).
Conclusion:
Supervised machine learning approaches can effectively predict Tc among workers wearing high-level PPE.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Personal Protective Equipment
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Body Temperature