A self-calibrating porphyrin-based optofluidic system with edge-deployable chemometrics for online fluoride
Sagar Rana1, Anupma Sharma1, Neena2
1Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India; CSIR-Central Scientific Instruments Organization, Chandigarh, 160030, India.
Abstract:
In this work, we report a self-calibrating two-channel flow system for a porphyrin-molecule-based optical sensor for the quantification of fluoride (F-) in drinking water, with online monitoring capabilities. The mechanism employs absorbance-based detection of fluoride ion (F-) using 5, 10, 15, 20-Tetraphenyl-21H, 23H-porphine iron(III) chloride (FeTPP) as the sensing probe. The absorbance spectrum of FeTPP was recorded for fluoride ions (F-) in the presence of various interferents including chloride (Cl-), bromide (Br-), iodide (I-), nitrate (NO3-), sulfate (SO42-), phosphate (PO43-), sulfite (SO32-), bisulfide (HS-), azide (N3-) and acetate (CH3COO-) to assess its applicability for real-time detection. Statistical analysis, in conjunction with a multivariate prediction model, has been implemented to estimate the sensitivity and predictive efficiency of the porphyrin sensor. The prediction model showed promising results with a coefficient of determination (R2) of 0.9983 ± 0.0009 and mean squared error (MSE) of 0.0018 ± 0.0068 in the absence of interferences, and R2 of 0.9928 ± 0.0018 and MSE of 0.0472 ± 0.0422 in the presence of interferences. The effect of environmental parameters such as pH and temperature was also studied to develop a compensated prediction model that yielded a coefficient of determination (R2) of 0.9867 ± 0.0039 and MSE 0.0590 ± 0.0718. Furthermore, an online fluoride monitoring system has been designed, which includes a flow system with two parallel channels for the chemosensor and the water sample, a compact optical detector unit with an integrated LED and lens assembly, a microcontroller, and a display unit for data acquisition and user interface. The edge-deployed chemometrics, which included a multivariate prediction model, was configured in the microcontroller to predict the fluoride concentration in water. The proposed system showed congruence with recorded absorbance data for the fluoride concentration in a range from 0.1 to 10 ppm. The efficiency of the sensor was also effectively demonstrated for real water samples spiked with fluoride ions. These encouraging findings provide a firm foundation for the implementation of practical field applications in water quality sensing.
More Related Videos
09:36Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings
Published on: February 3, 2021
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025