Real-Time Monitoring with a Wristwatch-Type Sodium- and Potassium-Ion Sensor Using a Screen-Printed Liquid-Junction
Isao Shitanda1,2, Takuma Fujisawa1, Noya Loew1
1Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan.
Abstract:
Wearable ion sensors have gained increasing attention for the continuous noninvasive monitoring of ions in body fluids such as sweat. However, printed reference electrodes commonly used in potentiometric ion sensors require prolonged conditioning to achieve stable potentials, which limits practical wearable applications. Here, we integrated a screen-printed liquid-junction reference-electrode architecture with dual Na+- and K+-selective electrodes in a wearable wristwatch-type sensing platform. The liquid-junction reference becomes operable without the prolonged preconditioning required by poly-(vinyl butyral) (PVB)-type printed references. The sensor exhibited sensitivities of 48.3 mV decade-1 for Na+ and 46.4 mV decade-1 for K+. The printed reference electrode drifted by approximately 6 mV over 3000 s against a commercial reference in 10 mM NaCl. A control reference electrode fabricated without the liquid-junction layer showed a substantially greater dependence on the external KCl concentration, supporting the functional role of the liquid-junction layer. A fabric layer and a superabsorbent-fiber (SAF) layer were incorporated as a physical barrier and a sample-handling structure. A wristwatch-type wireless device was designed and constructed for real-time data acquisition, wireless transmission, and local storage on an SD card. The complete system was deployed at an active construction site. During on-body testing with a volunteer construction worker, the system acquired Na+- and K+-responsive potentiometric signals in real time, which were converted to apparent ion concentrations using aqueous calibration curves, over a working period of approximately 2 h 45 min.
Related Concept Videos
Potentiometry: Membrane Electrodes
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Amperometry: Overview