Smooth total variation regularization for interference detection and elimination (STRIDE) for MRI
Alexander Mertens1, Diego Martinez2, Amgad Louka2
1University of Toronto - St George Campus, 27 King's College Cir, Toronto, ON M5S 1A1, Toronto, Ontario, M5S 1A1, Canada.
Objective:
MRI is increasingly required to operate near electronic devices that emit dynamic electromagnetic interference (EMI). Existing reference-channel EMI removal methods estimate a transfer function between EMI sensors and imaging coils from the measured data alone, and do not use prior knowledge about the structure of MR images. We develop and validate an EMI removal method that uses the inherent spatial smoothness of MR images as an additional prior, demonstrated on a head-only 0.5T scanner.
Approach:
Smooth Total variation Regularization for Interference Detection and Elimination (STRIDE) operates in the image domain. For each image column, EMI sensor data are combined and subtracted from the imaging coil data such that the L2 norm of the total variation (TV) along the readout direction is minimized. This exploits the smoothness of MR images, a property well-known in compressed sensing but not previously used in EMI removal. STRIDE was evaluated on phantom and in-vivo brain datasets under EMI scenarios replicating sources encountered at our affiliated hospitals, and compared against two implementations of External Dynamic Interference Estimation and Removal (EDITER).
Main Results:
STRIDE produced visually better EMI removal, higher temporal signal-to-noise ratio, and larger EMI removal percentage than both EDITER implementations. STRIDE also resulted in lower or equal root-mean-square error than both EDITER implementations in all 8 phantom EMI conditions tested. These results held across both phantom and in-vivo datasets.
Significance:
STRIDE shows that incorporating known properties of MR images into the EMI removal problem provides meaningful improvements over methods that rely on measured data alone. The approach is deterministic, training-free, sequence-independent, and compatible with existing EMI sensor hardware. STRIDE therefore extends reference-channel EMI removal to scenarios where existing methods fail, particularly point-of-care and interventional MRI outside fully shielded environments, providing a complementary path to machine-learning approaches.
Related Concept Videos
Interference and Diffraction
Magnetic Resonance Imaging
Reconstruction of Signal using Interpolation
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
IR Frequency Region: X–H Stretching
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...