Impact of draining cannula position and configuration under high-flow extracorporeal CO2 removal (ECCO2R) on
Jonathan Charbit1, Clara Muller2, Mehdi Girard2
1Département d'Anesthésie Réanimation Lapeyronie, Critical Care Unit, Hôpital Lapeyronie, Lapeyronie University Hospital, 371 Avenue du Doyen G. Giraud, 34295, Montpellier Cedex 5, France. j-charbit@chu-montpellier.fr.
Abstract:
The main goal of the present study was to demonstrate the influence of draining cannulas' position and high-flow extracorporeal CO2 removal (ECCO2R) configuration on recirculation and extracorporeal decarboxylation. This single-center retrospective study was conducted between January 2018 and May 2024. All patients who received a high-flow ECCO2R (extracorporeal blood flow ≥ 2 L/min) were included. Four configurations each used an ECMO device, two single-lumen cannulas, and an ipsilateral cannulation site: CENTRAL DRAINAGE configurations (central jugular-jugular and central femoro-femoral), DISTAL DRAINAGE configurations (distal jugular-jugular and distal femoro-femoral). Recirculation coefficient and CO2 elimination were assessed between these configurations. The influence of the configuration and recirculation coefficient on CO2 elimination was studied by multivariable mixed linear model. Eighteen patients were treated with high-flow ECCO2R. Extracorporeal blood flows (median of 2.6 L/min [IQR, 2.0‒2.6 L/min]) were comparable between the configurations (P = 0.33), although values higher than 2.5 L/min were observed in CENTRAL DRAINAGE configurations. Median CO2 elimination was 110 mL(STPD)/min (IQR, 83‒149 mL(STPD)/min). Recirculation coefficient was significantly higher with the DISTAL DRAINAGE configurations (59% [IQR, 51‒71%] versus 9% [IQR, 15‒22%], respectively; P < 0.001). Consequently, CO2 elimination was significantly lower with the DISTAL DRAINAGE configurations (58 mL(STPD)/min [IQR, 44‒72 mL(STPD)/min] versus 122 mL(STPD)/min [IQR, 96‒159 mL(STPD)/min], respectively; P = 0.003). Both DISTAL DRAINAGE configurations and high recirculation coefficient were significantly associated in multivariable analysis with a reduction in CO2 elimination (P < 0.001). We evaluated four different configurations of high-flow ECCO2R using single-lumen cannulas allowing either a central or a distal drainage. A central drainage configuration gave better rheological conditions and lower recirculation, leading to better extracorporeal decarboxylation.
More Related Videos
09:54Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Hemodialysis II: Procedure and Complications